Bridge Deck slab design example as per IRC || Slab Bridge Design Example || Bridge Design Using LSM Method-Part 4
We get,
Maximum bending moment for dead load=241.344 kN.m
Maximum bending moment for live load=163.967 kN-m
Total design
bending moment for Dead Load and Live Load=
=1.35xBMDL + 1.5xBMLL
=1.35x241.334kN-m+1.5x163.967
kN-m
=571.751 kN-m/m-width
Maximum shear force for dead load=100.56 kN.
Maximum shear force for live load =71.66kN.
Total Design
shear force for Dead Load and Live Load=
=1.35xVDL + 1.5xVLL
=1.35x100.56
kN + 1.5x71.66 kN
=243.246 kN.
1. Checking Depth Of Slab:
We using materials: Concrete M30 and Steel: fy-415
We know moment of resistance by concrete
Mu=0.138fckbd2 (for fy: 415)
405.301x106=0.138x30x1000xd2
d=312.888 mm<700mm (provided effective depth) ( Hence, ok)
2. Design of Main Steel Bars:
Check section is under-reinforced or over-reinforced section.
Maximum depth of neutral axis (as per IS 456: 2000, Clause-38.1, page 70)
Xu(max)=0.48xd
=0.48x700
=336mm
The actual depth of neutral axis:
Ultimate moment of resistance by concrete=
Mu=0.36fckXub(d-0.42Xu)
571.751x10^6=0.36x30.Xu.1000(700-0.42xXu)
52939.91=700Xu-0.42Xu^2
0.42Xu^2-700Xu+52939.91=0
After calculating the equation
Xu=1587.25mm or 79.41mm
Here, Xu=1587.25mm is not acceptable because overall depth of slab is
750mm.
So, Xu=79.41mm
Xu=79.41mm< Xu(max)=336mm
Hence, this section is under-reinforced section. LSM method is
applicable to design under reinforced and balanced reinforced sections.
If the
actual depth of the neutral axis (Xu) is greater than maximum depth of neutral axis
(Xumax), the section shall be redesigned. LSM method is not applicable to design
over reinforced section. (from IS 456:
2000, Clause-38.1 G.1.1(c), page-96)
Moment of resistance by steel reinforcements:
Mu=0.87fyAst(d-0.42Xu)
571.751x10^6=0.87x415xAst(700-0.42x79.41)
Ast=2375.435mm2
No of bars= Area of steel/area of individual steel bar=(2375.435)/(π/4x20^2)= 7.56
Spacing
=1000/7.564=132.197mm
Providing 20mm diameter bars @130mm
spacing C/C.
So, Provided area of steel
reinforcement, Ast=2416 mm2
2. 3. Check the percentage of steel:
(According to IS 456:2000, Clause 26.5.2.1, page-48)
For Slabs:
Minimum percentage of steel 0.15% of A-gross for Fe 250 and 0.12% of
A-gross for Fe 450. Maximum percentage of steel 4%.
Minimum
steel reinforcement=0.12% of bD
=0.12x1000x750/100
=900 mm2 <Provided area of steel
reinforcement (Ast=2416 mm2) (Hence safe)
3. 4. Check Shear
Stress:
As per IS 456: 2000, Clause 40.1, page 72
Picture-1: Check Shear Stress for Slab Bridge Design Example |
τv = Vu/ b.d
=243.246/(1000x700) kN/mm2
=0.000347494
kN/mm2
= 0.347494
N/mm2
Percentage of steel
=Astx100/bd
=2416x100/(1000x700)
=0.345
We get permissible shear strength of concrete for grade M30 (as per IS 456 2000, Table-19, page 73)
Permissible shear stress=τc
= 0.419 N/mm2
Nominal shear stress (τv) is less
than permissible shear stress (τc).
Hence,
there is not required to provide shear reinforcement.
5. Calculation for distribution bar:
Bending
moment for distribution reinforcement:
M=0.2BMDL+0.3BMLL (As per IRC 21, Clause 305.18.1, page 56)
Design
bending moment for distribution reinforcement
=1.35x(0.3x241.334)kN-m+1.5x(0.2x163.967)
kN-m (multiplied by safety factor 1.35 for Live Load and 1.5 for Dead Load).
=146.930 kN-m
Find out
effective depth for distribution bar=d’
d’=(oval all
depth)-(clear cover)-(diameter of main bar)-(half diameter of distribution bar).
Let's use 12 mm diameter distribution bar.
d’=(750-40-20-12/2)
mm
d’=684mm
We know,
Mu=0.87fy.Ast.d (1-Ast.fy/bdfck)
146.930x10^6=0.87x415xAstx684(1-Astx415/1000x684x30)
594.959= Ast(1-Astx2.022x10^-5)
Ast2(2.022x10^-5)-Ast+594.959=0
Ast=48854mm2 or 603mm2
Take the acceptable value 603 mm2
But percentage of steel will be P(t)=603/ (1000x750)
=0.000804
=0.0804% of bD< Minimum steel reinforcement=0.12% of bD
So, provide minimum area of distribution bars.
=Area of distribution bars=0.12% of bD
=0.12x1000x750/100
=900 mm2
Spacing=1000x (π/4x12^2)/900
=125.71 mm
Picture-2: Main bars and distribution bars details. |
You may visit my youtube channel:
1. Slab-Bridge-Design-In-Midas-Civil-as Per Indian Code IRC 112
More Posts:
1. RCC Slab Bridge Analysis And Design Step-By-Step Manually || Part-1
2. Live Load Bending Moment IRC Class 70R Tracked Vehicle for Slab Bridge Design Manually || Part 2
3. Maximum Shaer Force Calculation for IRC Class 70R Tracked Vehicle || Slab Bridge Design Manually || Part 3
4. Bridge Deck Slab Design Example as per IRC || Slab Bridge Design example || LSM Method || Part 4
1 Comments
👍
ReplyDeletePlease feel free to suggest us to improve the content (Is it informative or not)